I. Product performance
Advanced constant current and constant voltage charge
Adopt CPU control and pulse width modulation (pwm) technology to precisely control the charging current and output voltage of the charger, which ensures the full charge and avoids the over-charging.
Reliable charge protection
The charge has battery over-voltage protection, output short circuit protection to control the battery to make intelligent and safe charge according to the detected battery status.
II. Product technical index
Charger model |
GY-FPC24 |
GY-FPC36 |
GY-FPC48 |
GY-FPC72 |
Working temperature |
Room temperature +5¡æ-37¡æ |
Input voltage |
AC220V 50Hz £¨AC110V 50Hz for special situation£© |
Rated voltage |
24V |
36V |
48V |
72V |
Constant current charging current |
2.0A¡À5% |
2.0A¡À5% |
2.0A¡À5% |
2.0A¡À5% |
Constant current charging voltage |
25.6-26.2 |
40.3-41.1 |
54.9-56.1 |
80.6-82.2 |
Open circuit voltage |
25.9 |
40.7 |
55.5 |
81.4 |
Applicable battery type |
Coslight Li-Fe 24V |
Coslight Li-Fe 36V |
Coslight Li-Fe 48V |
Coslight Li-Fe 72V |
III. Product instruction
1. Connect the output plug into the charger, and check whether the input and output plugs are loosen.
2. Connect the output plug of charger into the battery charging interface, then connect the power supply plug of charger to the indoor power supply.
3. The charger adopts constant current and constant voltage charging method, and the battery can be fully charged within 4-6 hours according to different battery discharge depths. Unplug the power supply of charger after the battery is fully charged, then unplug the output plug of charger.
4. Do unplug the power supply plug of charger in the idle time or after the charge is finished.
5. Charger indication status specification
¡°Red¡± LED shows that the battery is in normal charging status.
¡°Green twinkling¡± shows that the battery has been fully charged, and been in constant voltage balanced status.
¡°Green¡± shows that the constant voltage balance has been finished, and the battery can be separated from the charger and put into normal use.
IV. Maintenance and notice
The charger must be applied with Coslight Li-Fe battery in strict accordance with the requirement, this charger is forbidden to charge any non Coslight Li-Fe battery!
High voltage in the charger, dangerous, please contact with the franchiser or manufacturer if there is any failure, the user and other personnel except for the professional maintenance personnel of this company are forbidden to open the charger!
Use the charger and battery in the indoor environment with good ventilating and cooling condition, the charger and battery are forbidden to use in the damp environment with high temperature, flammable and explosive gas.
In the charging process, if the ¡°red light¡± or ¡°green twinkling¡± is continuously on for over 6 hours, and the service time of battery is obviously reduced, we suggest send the battery to the franchiser or manufacture for inspection and maintenance.
Please carefully read the instruction before use, and the manufacturer will not be liable for any loss caused by incorrect operation! |